CM-3700A

Konica Minolta's top of the range spectrophotometer for reflectance and transmittance colour measurement. The best benchtop spectrophotometer for customers requiring absolute accuracy of liquid or solid samples. Ideally suited to applications like colour matching or for specification of colour to a global supply chain. The CM-3700A can also measure haze and has an adjustable cut-off UV filter for samples with OBAs.

  • Reference grade Benchtop Instrument
  • Wavelength range 360-740nm
  • d:8° Sphere Geometry
  • Reflection & Transmission
  • 3 Apertures SAV / MAV / LAV
     

“State of the Art” spectrophotometer for maximum performance in colour measurement


Proof of Konica Minolta’s leadership in advanced optical technology, a true "State of the Art" instrument. In every detail and without compromise, the CM-3700A is designed for maximum performance making it an ideal choice for a reference instrument in a global colour management network. The CM-3700A allows colour measurement of solid, translucent and transparent samples in reflectance and transmittance.

The optical system is designed and manufactured without compromise, exceeding the requirements of international standards while offering superior levels of inter-instrument agreement.

The superiority of the CM-3700A in terms of absolute accuracy and long term stability, especially on very dark or high chromaticity colours, has been recognised by top ranking institutes and leading companies throughout the colour industry.

 

Features

Features
The flagship spectrophotometer from Konica Minolta, meeting the highest expectations in absolute accuracy, short- and long-term stability and unsurpassed inter instrument agreement levels to act as reference instrument in a global colorimetric network.
  • Built without compromise: Two flat holographic gratings with silicon photodiode arrays, one each for the sample and feedback channel, together with the high power xenon flash ensures highest absolute accuracy and repeatability
 
  • Eliminates temperature drift: The entire optical system is mounted on a stainless steel casted chassis
 
  • Motorized gloss trap: Measurements of samples with (Specular component included - SCI) and without ( Specular component excluded - SCE) surface conditions
 
  • Motorised UV cut filter: Exclude the impact of any optical brightening agents (OBA) in samples such as textiles, pulp and paper.

CM-3700A Benchtop Spectrophotometer

A guided tour of the CM-3700A Benchtop Spectrophotometer from Konica Minolta

Specifications & Downloads

Specifications & Downloads
Model Spectrophotometer CM-3700A
Illuminating/viewing system d:8° (diffused illumination; 8° viewing angle); switchable: di:8° SCI (specular component included) or de:8° SCE (specular component excluded; meets ISO and DIN standards for d:8° geometry; also meets CIE and ASTM standards for d:0° geometry. Transmittance: d:0° (diffuse illumination/0° viewing angle)
Detector Silicon photodiode array with flat holographic grating
Wavelength range 360 nm to 740 nm
Wavelength pitch 10 nm
Half bandwidth Approximately 14 nm average
Measurement range 0 to 200%; Resolution: 0.001%
Photometric range Pulsed xenon arc lamp
Measurement time 0.6 to 0.8 sec. (to start of data output)
Illumination/measurement areas Reflectance: Changeable between LAV, MAV, and SAV
LAV: Ø 28 mm illumination / Ø 25.4 mm measurement
MAV: Ø 11 mm illumination / Ø 8 mm measurement
SAV: 5 × 7 mm illumination / 3 × 5 mm measurement
Transmittance: Approx. Ø 20 mm
Repeatability When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: ;
Spectral reflectance: Standard deviation within 0.05%
Chromaticity: Standard deviation within ΔE*ab 0.005
When black tile (BCRA Series II; reflectance: 1%) is measured 30 times at 10-sec. intervals after white calibration has been performed:
Spectral reflectance: 380 to 740 nm: Standard deviation within 0.02%
360 and 370 nm: Standard deviation within 0.04%
Chromaticity: Standard deviation within ΔE*ab 0.05
Inter-instrument agreement (LAV) Mean ΔE*ab 0.08 (typical) Average for 12 BCRA Series II color tiles.
Max ΔE*ab 0.3 (corresponds to ΔECMC 0.2) for any of 12 BCRA Series II color tiles compared to values measured with master body
Temperature drift Spectral reflectance: Within ±0.10%/°C
Color difference: Within ΔE*ab 0.05/°C
UV adjustment Computer controlled; continuously variable
Specimen conditions for transmittance measurements Sheet, plate, or liquid form up to a maximum thickness of approximately 50 mm and unlimited sample length
Interfaces USB 1.1
Power AC 100 to 240V 50/60Hz 25VA (using included AC adapter)
Operating temperature/humidity range 13 - 33°C, relative humidity 80% or less (at 33°C) with no condensation
Storage temperature/humidity range 0 - 40°C, relative humidity 80% or less (at 35°C) with no condensation
Dimensions (W × H × D) 271 × 274 × 500 mm (10-11/16 x 10-3/4 x 19-11/16 in.)
Weight 18 kg (39.7 lb.)
Standard accessories White Calibration Plate; Target Mask (3 × 5 mm); Target Mask (Ø 8 mm); Target Mask (Ø 25.4 mm); Zero Calibration Box; AC Adapter; USB Cable (3 m); Accessory Case; Dust Cover
Optional accessories Colour Data Software SpectraMagic NX; Transmittance Specimen Holder; Glass Cells (2 mm, 10 mm, 20 mm); Plastic Cells (2 mm, 10 mm, 20 mm); Transmittance Zero Calibration Plate and 
others
Specifications are subject to change without prior notice.

Download Catalogue

Learn more about Spectrophotometer
CM-3700A in our catalogue

Download

Accessories

Accessories

Optional accessories for CM-3700A

            

Transmittance Zero Calibration plate CM-A100

The Transmission Zero Calibration Plate CM-A100 is required to block the light path for zero calibration in transmittance measurement mode. The black and mat coating of the plate absorbs also stray light within the transmission chamber of the instrument.

Item Order Code: 1864-712

 

Transmittance Specimen Holder CM-A96

For precise positioning of transparent plates, films or other transparent samples for transmittance measurements. Holds the Rectangular Cells CM-A97 (2 mm path), CM-A98 (10 mm path), CM-A99 (20 mm path) and the Rectangular Disposal Cells CM-A CM-A130 (2 mm path), CM-A131 (10 mm path) and CM-A132 (20 mm path) or the Flow Cell CM-A508 (10 mm path) always in perfect and repeatable position for precise transmittance measurements of liquids.

Item Order Code: 1864-708

   

Glass Cell 2 mm CM-A97

Glass cell made of optical glass for precise transmittance measurement of transparent liquids. The optical path is 2 mm and therefore perfect for liquids with high optical density.

Item Order Code: 1864-709

   

Glass Cell 10 mm CM-A98

Glass cell made of optical glass for precise transmittance measurement of transparent liquids. The optical path is 10 mm and recommended for liquids with normal optical density. Recommended also for reflectance measurements of opaque liquids in combination with Cell-Holder CM-A509.

Item Order Code: 1864-710

   

Glass Cell 20 mm CM-A99

Glass cell made of optical glass for high precision transmittance measurement of transparent liquids. The optical path is 20 mm and recommended for liquids with low optical density. Also suitable for reflectance measurements of opaque liquids, paste, powder or grains in combination with Cell-Holder CM-A509.

Item Order Code: 1864-711

   

Plastic Cell 2 mm CM-A130

Disposal plastic cell with an optical path of 2 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with high density.

Item Order Code: 1870-715

   

Plastic Cell 10 mm CM-A131

Disposal plastic cell with an optical path of 10 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with normal density. Also suitable for reflectance measurements of water based opaque liquids in combination with Cell-Holder CM-A509.

Item Order Code: 1870-716

   

Plastic Cell 20 mm CM-A132

Disposal plastic cell with an optical path of 20 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with lower density. Also suitable for reflectance measurements of water based opaque liquids or paste, none aggressive powders or grains in combination with Cell-Holder CM-A509.

Item Order Code: 1870-717

 

PET Pre-Form Holder CM-A520

The PET-Pre-Form Holder CM-A520 allows precise positioning of transparent Pre-forms in the transmission chamber of the instrument. The rail guide of the holder allows horizontal movements of the pre-form to define the area for the measurement.

Item Order Code: B027167

 

Black Glass Tile CM-A511

High gloss black glass tile with high absorption. Due to the extreme long term stability perfect to use as background standard.

Item Order Code: 9970-1109

 

Tube Holder CM-A517

This special holder allows easy positioning and measurement of tubes such as pencils or similar. The dimension of the Tube Holder is 50 x 50 mm and thus suitable for short and long samples. It can be used for samples with a diameter from 8 to 24 mm. To prevent drop down the tube holder is delivered with a self-adhesive plastic ferro plate.

Item Order Code: B027157

Request a Quote