CR-410C

The large aperture CR-410 with specially modified firmware and purpose designed sample holder is used to provide colour measurements of coffee at all stages of the production process using industry standard measurements.

  • Ø 50mm measurement aperture
  • Sample holder jig
  • SCAA index data for coffee products
  • Portable

Customised CR-410 tristimulus colorimeter specifically for measuring the colour and quality of coffee throughout production

The CR-410C handheld coffee colorimeter is specifically designed to measure the colour of whole green beans, roasted beans, and roasted coffee using industry standard measurements.

The CR-410C is a tristimulus colorimeter that measures colour using filters with a close match to the spectral sensitivity function of the human eye. Using this technology, operators can achieve traceable measurement data for colour and colour difference that correlates with human perception.

 The device firmware contains the Speciality Coffee Association of Americas (SCAA) Speciality coffee index to quickly, simply and repeatably calculate the colour difference from a standard, roast level (light, medium, medium dark, dark) and pass/fail tolerances. 

Utilising this cost effective and portable setup, the operator can accurately measure the colour of coffee in various forms: whole green beans, roasted beans, roasted and lyophilized (Freeze Dried).

 

Features

Features
  • Ø 50mm measuring aperture: averages a large area for repeatable results.
 
  • Built- in backlit LCD display: colour measurement, colour difference and tolerance data are plainly displayed and visible even in dark conditions.
 
  • Custom jig and measuring cups: purpose designed instrument holder guides one or 3 samples into position under the aperture to ensure repeatable measurements and best practice sample presentation.
 
  • Battery or AC Power: The CR-410C can be powered either by AAA batteries or AC power in order to minimise downtime.
 
  • Enhanced reporting and storage via PC: connect the system to optional SpectraMagic NX software to present data in standard or user generated templates.

Specifications & Downloads

Specifications & Downloads

Model

CR-410 Head

Illuminating/viewing system

Wide-area illumination:0° viewing angle; specular component included

Detector

Silicon photocells (6)

Display range

Y: 0.01% to 160.00% (reflectance)

Light source

Pulsed xenon lamp

Measurement time

1 sec.

Minimum measurement interval

3 sec.

Battery performance

Approx. 800 measurements (when using batteries under Konica Minolta’s testing conditions)

Measurement/illumination area

Ø 50 mm/ Ø 53 mm

Repeatability

Within ΔE*ab 0.07 standard deviation (when the white calibration plate is measured 30 times at intervals of 10 seconds)

Inter-instrument agreement

ΔE*ab: within 0.8
Average of 12 BCRA Series II colors

Observer condition

CIE: 2° Standard Observer

Illuminant condition

CIE: C, D65

Tolerance judgment*

Colour difference tolerance (box tolerance and elliptical tolerance)

Color space/colorimetric data*

XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell (Illuminant C only), CMC (l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI/Tw (Illuminant D65 only), WI ASTM E313 (Illuminant C only), YI ASTM D1925 (Illuminant C only), YI ASTM E313 (Illuminant C only), User index (Up to 6 can be registered from computer), SCAA scale

Languages* (Display)

LCD: English (default), German, French, Italian, Spanish, Japanese

Storable data sets

1,000 (Measuring head and data processor save different data)

Color-difference target colors

100

Calibration channels*

20 channels (ch00: White calibration; ch01 to ch19: User calibration)

Display*

Chroma values; color difference values; PASS/WARN/FAIL display

Interface / Baud rate*

RS-232 compliant (for data processor/PC)
* Baud rate: 4,800, 9,600, 19,200 (bps); Set at 9600 when shipped from factory

Power source

Four AAA size alkaline or Ni-MH batteries
AC Adapter AC-A305 AC100 – 240 V 50/60Hz

Dimensions (W × H × D)

102 × 244 × 63 mm

Weight

Approximately 570 g
(including 4 AAA size batteries and not including RS-232C cable)

Operating temperature/humidity range

0 – 40°C, relative humidity 85% or less with no condensation

Storage temperature/humidity range

-20 – 40°C, relative humidity 85% or less with no condensation

Other

LCD backlight ON/OFF function (When on, backlight stays ON for 30 seconds after last key or measurement operation)

The “*” mark indicates functions available only when the Data Processor is connected or when the required settings have been made.
 

Name Data Processor
Model DP-400
Display range Y: 0.01% to 160.00% (reflectance)
Measurement time 1 sec.
Minimum measurement interval 3 sec.
Battery performance Approx. 800 measurements (when using batteries under Konica Minolta's testing conditions)
Illuminant condition C, D65
Display Chroma values; color difference values; colour difference graphs; PASS/WARN/FAIL display
Tolerance judgment* Colour-difference tolerance (box tolerance and elliptical tolerance) Only for display function
Colour space/ colourimetric data* XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell (Illuminant C only), CMC (l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI/Tw (Illuminant D65 only), WI ASTM E313 (Illuminant C only), YI ASTM D1925 (Illuminant C only), YI ASTM E313 (Illuminant C only), User index (Up to 6 registered in the measuring head can be used)
Languages* (Display) LCD: English (default), German, French, Italian, Spanish, Japanese
Storable data sets Max. 2000 pieces of data (divided into 100 pages)
Deletion and Undoing of selected stored data (one or all data) are possible
Colour-difference target colours* Only for the operating function (100 pieces of data when the measuring head is connected; input of measurement values or numeric) (Independent from page function)
Calibratiom channels* Only for the operating function (20 channels when the measuring head is connected)
(Channel 00: White calibration; Channels 01 through 19: User calibration)
Page function 100 pages
Display Dot-matrix LCD with backlight (16 characters x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384-dot line thermal printer (can also print graphs); Automatic printing for each measurement (can be set not to print)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement* Date and time display: Year, month, day, hour, minute
Timer: 3 seconds to 99 minutes (Some measurement modes require more than 3 seconds)
Interface RS-232C compliant Baud rate (bps): 19200 fixed (when connected to PC); when measuring head is connected, baud rate is automatically set to that of the measuring head.
Power source Four AA-size alkaline or Ni-MH batteries
AC Adapter AC-A305 AC100 - 240 V 50/60Hz
Dimensions (W x H x D) 102 × 244 × 63 mm
Weight Approx. 600 g (not including batteries and paper)
Operating temperature / humidity range 0 - 40°C, relative humidity 85% or less with no condensation
Storage temerature / humidity range -20 - 40°C, relative humidity 85% or less with no condensation
Other specifications* User calibration function (multi-calibration/manual calibration); Measurements for automatic averaging function; Print on/off function; CR-400 measurement data import function; All colour space print on/off function; Data protection on/off function; Backlight on/off function; Buzzer on/off function; Display color limit function; Remote mode (stored data output); Character input function (alphanumeric)
Standard accessories Roll paper (1); RS-232C Cable CR-A101 (Head-DP)
Optional accessories Shoulder Strap SS-01; Hard Case CR-A103; Roll Paper DP-A22 (5 rolls); RS-232C Cable CR-A102 (for PC); CR-400 Utility Software CR-S4w; Colour Data Software SpectraMagicNX CM-S100w

The "*" mark indicates functions that can be used only when the measuring head is connected. Specifications are subject to change without prior notice.

Accessories

Accessories

Optional accessories for CR-410C

 

Powder Sample Holder with Three Cup Holder

This sample holder enables the instrument to be held in position during powder sample measurement. Powdery samples are placed in the cups that are held in a sliding tray with three cups. This holder is best suited for fine powders although granular materials can be used in it as well. Enables the quick, easy, and precise measurement of powder with a CR-410.

Item comes with three cups and is not recommended for liquids.

Item Order Code: B027057

   

Cup for Powder Sample Holder

Spare cups for B027057 and B027058

Item Order Code

 

 

Granular Attachment CR-A50

For measurements of powders, pastes, grains or other small sized granular material. The low reflectance glass plate protects the sample surface against disorientation and prevents specimen material to enter the instrument. The set includes one retaining ring each to adjust the measuring area accordingly to either CR-400 or CR-410.

Item Order Code: 1829-751

   

Glass Plate for CR-A51 (for CR-A50)

Replacement low reflectance glass plate for CR-A50 Granular Attachment.

Item Order Code: 1829-752

   

Retaining Ring Set CR-A52

Replacement ring set for CR-A50 Granular Attachment. The set consist of one ring each for CR-400 and CR-410.

Item Order Code: 1829-753

 

Light Protection Tube with Glass Protection CR-A33e (only for CR-410)

Light projection tube for measurement of pasty, wet or moist samples. The protection glass plate prevents specimen from entering the instrument.

Item Order Code: 1849-735

 

Cell Holder CR-A501 (only for CR-410)

For measurements of powders, grains and granular materials in combination with the Glass Cell CR-A504. The measuring head is set to up-side down position and the Cell Holder CR-A501 precisely fixes the position of the Glass Cell CR-502.

Item Order Code: 9970-219

 

Glass Cell CR-A502 (only for CR-410)

Glass Cell made of optical glass for measurements of powders, pastes, grains and small granular materials. Diameter of the cell 60 mm. For precise positioning the Cell Holder CR-A501 is recommended.

Item Order Code: 9970-220

 

Vertical Stand USD CM-A516

The CM-A516 Vertical allows aligning the instrument in Up-Side-Down position and secures that the instrument cannot get out of balance by using the Cell-Holder CR-A503 for CR-400 and CR-A501 for CR-410.

Item Order Code: B027154

   

Hard Case CR-A103

For comfortable hand carrying and storage of measuring head, data processor and accessories.

Item Order Code: 1878-600

   

Data Cable CR-A102 RS232c

Connection cable between measuring head or data processor and PC. For PC terminals with 9 pin SUB-D connecter. Length of the cable 2 m.

Item Order Code: 1878-704

Related Industries and Applications